BZSQY - LC20030, POTASSIUM PERMANGANATE SOLUTIONS, (SUPDAT)

  • MSDS: BZSQY
  • Manufacturer: LABCHEM INC
  • Product Name: LC20030, POTASSIUM PERMANGANATE SOLUTIONS, (SUPDAT)
  • National Stock Number: 6810-00N070216
Product Identification

Product ID:LC20030, POTASSIUM PERMANGANATE SOLUTIONS, (SUPDAT)
MSDS Date:03/11/1995
FSC:6810
NIIN:00N070216
MSDS Number: BZSQY

Responsible Party
LABCHEM INC
200 WILLIAM PITT WAY
PITTSBURGH, PA 15238
US

Emergency Phone: 412-826-5230

Info Phone: 412-826-5230

Preparer: AL BERANEK

Cage: EO318

Contractor
LABCHEM, INC.
PITTSBURGH, PA 15238 US

Telephone: 412-826-5230

Cage: 0MX47

Ingredients

PERMANGANIC ACID, POTASSIUM SALT; (POTASSIUM PERMANGANATE)

CAS: 7722-64-7

RTECS: SD6475000

Fraction By Weight: 0.3-5%

OSHA PEL C 5 MG(MN)/M3

ACGIH TLV: 5 MG(MN)/M3

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: BALANCE

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:SEE INGREDIENT 1
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:MAY CAUSE SORE THROAT,
RESPIRATORY TRACT IRRITATION, DYSPNEA AND LABORED BREATHING. MAY
CAUSE IRRITATION, REDNESS, AND STAINING OF SKIN. MAY CAUSE
IRRITATION, TEARING AND STAINING OF THE EYES. M AY CAUSE BURNING OF
THE THROAT, DRYING OF MUCOUS MEMBRANES, NAUSEA, VOMITING, MODERATE
GI IRRITATION. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:CHRONIC:MAY CAUSE DERMATITIS AND
CONJUCTIVITIS. TOXICITY:POSTASSIUM PERMANGANATE SOLUTION IS AN EYE,
SKIN, MUCOUS MEMBRANE IRRITANT. POISONING MAY AFFECT KIDNEY.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE FROM EXPOS IMMED. IF BRTHG HAS STOPPED, GIVE
ARTF RESP. GET MED AID AT ONCE. SKIN:REMOVE CONTAM CLTHG. WASH
AFFECTED AREA W/SOAP & LG AMTS OF WATER UNTIL NO EVIDENCE OF CHEM
REMAINS (ABOU T 15-20 MIN). GET MED AID AT ONCE. EYE:WASH W/LG AMTS
OF WATER FOR AT LST 15 MIN OCCAS LIFTING LIDS UNTIL NO EVIDENCE OF
CHEM REMAINS. INGEST:DO NOT INDUCE VOMIT. NO SPECIFIC ANTIDOTE.
TREAT (SUP DAT)

Fire Fighting

Flash Point:NOT COMBUSTIBLE
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, WATER SPRAY.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. MOVE CNTNRS FROM FIRE AREA IF POSS, COOL CNTNRS EXPOSED TO FLAMES
W/WATER, APPLY FROM FAR DIST (SUPP DATA)
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:FOR SMALL LIQUID SPILLS, TAKE UP WITH SAND,
EARTH/OTHER ABSORB MATL & PLACE IN CNTNRS FOR LATER DISP. FOR LG
SPILLS, DIKE FAR AHEAD OF SPILL FOR LATER DISP. ISOLATE AREA & DENY
ENTRY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL, DRY AREAS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:HIGH LEVELS-NIOSH/MSHA APPROVED SUPPLIED-AIR
RESPIRATOR WITH FULL FACEPIECE, HELMET OR HOOD, NIOSH/MSHA APPROVED
SELF-CONTAINED BREATHING APPARATUS WITH FULL FACEPIECE.
FIREFIGHTING-NIOSH/MSHA APPROVE D SCBA WITH FULL FACEPIECE.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
SHOWER . WEAR PROTECTIVE CLOTHING TO PREVENT CONTACT WITH SKIN.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR TRADE/PART #:0.63%-5%, 0.1N-1.0N. FIRE FIGHT PROC:UNTIL FIRE IS
OUT. FOR MASSIVE FIRE IN STOR AREA, USE UNMANNED HOSE
HOLDER/MONITOR NOZZS. EVACUATE TO RADIUS OF 2500 FEET FOR
UNCONTROLLABLE FIRES . FIRST AID PROC:SYMPTOMATICALLY. GET MED AID
AT ONCE. EYE PROT:AND FULL LENGTH FACESHIELD .

Chemical Properties

Vapor Pres:14 (H*2O)
Vapor Density:0.7 (H*2O)
Spec Gravity:1.0-1.1
Evaporation Rate & Reference:>1 (ETHER=1)
Solubility in Water:SOLUBLE
Appearance and Odor:PURPLE LIQUID/ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL DECOMPOSITION RELEASES OXYGEN
WHICH GREATLY INCREASES THE RATE OF COMBUSTIBLE SUBSTANCES.

Disposal

Waste Disposal Methods:DISPOSAL SHOULD BE IN COMPLIANCE WITH FEDERAL,
STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.